The maintenance of the hyperbolic mixer should achieve these

Sep 07, 2024Leave a message

1. After running for 200-300 hours, the lubricating oil of the gearbox should be replaced and the internal oil stains should be cleaned. When working continuously for more than 10 hours a day, change the lubricating oil every three months. When working less than 10 hours a day, change the lubricating oil every six months.
2. Regularly check for abnormal sounds and temperature rise in rotating components.
3. Regularly check for any abnormal changes in current.
4. Regularly check the swing of the mixing shaft and promptly clean any tangled objects on the wheels and shaft.
5. After a long period of inactivity, check the insulation of the motor before restarting the equipment. At the same time, it can prevent sediment from settling for a long time, which can cause difficulty in starting and damage to the motor and impeller.
6. During normal operation, each shift should have a dedicated person inspect once or twice. Any abnormal situations, such as electrical leakage, abnormal noise, loose mixing shaft, or overall machine shaking, should be able to be identified. Stop the machine in a timely manner, identify the cause, and troubleshoot before continuing to operate.